X-Flow® Silicone Prostatic Catheters



X-Flow® prostatic silicone catheters from Coloplast feature large irrigation channels to prevent blocking and a clear catheter body to monitor and visualize post-operative fluid flow. The soft and biocompatible silicone material removes the risk of latex allergies and promotes patient comfort. A variety of sizes and tip configurations allow caregivers to tailor care according to their patient’s needs.
Quick Look
Performance and Safety
- Large bevel and eyes to ensure excellent drainage capacity.
- Wide irrigation and drainage channels to prevent blocking.
- Closed round tip for ease of placement of an introducer when needed.
- Stiff walls to facilitate clot evacuation.
- Clear catheter body to monitor drainage quality and visualize urine.
- All Silicone, to avoid any risk of allergy or toxicity.
Ordering Information
X-Flow® Silicone Prostatic Catheters (5 EA / Retail Box) | |||||
---|---|---|---|---|---|
Item | Ways | Type | Diameter (Fr) | Balloon (mL) | Length (cm) |
AB6118 | 3 | Couvelaire | 18 | 50 | 42 |
AB6120 | 3 | Couvelaire | 20 | 50 | 42 |
AB6122 | 3 | Couvelaire | 22 | 50 | 42 |
AB6124 | 3 | Couvelaire | 24 | 50 | 42 |
AB6518 | 2 | Couvelaire | 18 | 50 | 42 |
AB6520 | 2 | Couvelaire | 20 | 50 | 42 |
AB6522 | 2 | Couvelaire | 22 | 50 | 42 |
AB6524 | 2 | Couvelaire | 24 | 50 | 42 |
AB6218 | 3 | Delinotte | 18 | 50 | 42 |
AB6220 | 3 | Delinotte | 20 | 50 | 42 |
AB6222 | 3 | Delinotte | 22 | 50 | 42 |
AB6224 | 3 | Delinotte | 24 | 50 | 42 |
AB6718 | 2 | Delinotte | 18 | 50 | 42 |
AB6720 | 2 | Delinotte | 20 | 50 | 42 |
AB6722 | 2 | Delinotte | 22 | 50 | 42 |
AB6724 | 2 | Delinotte | 24 | 50 | 42 |
AB6318 | 3 | Dufour | 18 | 50 | 42 |
AB6320 | 3 | Dufour | 20 | 50 | 42 |
AB6322 | 3 | Dufour | 22 | 50 | 42 |
AB6324 | 3 | Dufour | 24 | 50 | 42 |
AB6418 | 2 | Dufour | 18 | 50 | 42 |
AB6420 | 2 | Dufour | 20 | 50 | 42 |
AB6422 | 2 | Dufour | 22 | 50 | 42 |
AB6424 | 2 | Dufour | 24 | 50 | 42 |
AB6A18 | 3 | Dufour | 18 | 30 | 42 |
AB6A20 | 3 | Dufour | 20 | 30 | 42 |
AB6A22 | 3 | Dufour | 22 | 30 | 42 |
AB6A24 | 3 | Dufour | 24 | 30 | 42 |
AB6018 | 3 | Straight | 18 | 50 | 42 |
AB6020 | 3 | Straight | 20 | 50 | 42 |
AB6022 | 3 | Straight | 22 | 50 | 42 |
AB6024 | 3 | Straight | 24 | 50 | 42 |
AB6618 | 2 | Straight | 18 | 50 | 42 |
AB6620 | 2 | Straight | 20 | 50 | 42 |
AB6622 | 2 | Straight | 22 | 50 | 42 |
AB6624 | 2 | Straight | 24 | 50 | 42 |
AB6C18 | 3 | Straight | 18 | 30 | 42 |
AB6C20 | 3 | Straight | 20 | 30 | 42 |
AB6C22 | 3 | Straight | 22 | 30 | 42 |
AB6C24 | 3 | Straight | 24 | 30 | 42 |
Brief Statement
Indications for Use: For short-term drainage of bladder urine, postoperative bladder irrigation-lavage, and for hemostasis of the prostatic fossa following prostate surgery.
Warnings:
- Using an iodine-based irrigation-lavage solution may damage some silicone catheters.
- Do not inflate the balloon beyond the maximum value indicated.
- Do not clamp the catheter. Use a plug if necessary.
- If the catheter needs to be secured, the adhesive must be applied to the connector.
- To lubricate catheters without a coating, a water-based lubricant is recommended.
- Reuse of this single-use product may create a potential risk to the user. Reprocessing, cleaning, disinfection, and sterilization may compromise product characteristics which in turn create an additional risk of physical harm to or infection of the patient.
Adverse Events: Several adverse events have been described with the use of balloon catheters. Some are related to the patient’s conditions, the others to the procedure or the device: bladder irritation symptoms, pain, urinary tract infection, encrustation and stone formation, urinary tract trauma.
See Instructions for Use for detailed information regarding warnings/precautions, adverse events prior to using this product.
For further information, contact Coloplast Corp at 1-800-258-3476 and/or consult the company website at www.coloplast.com.
Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.
Request Additional Information
I understand that by providing all of the below information and clicking “Send”, I am giving Coloplast my consent to be contacted for the reasons I described in my message.